Skip to content
Sector
Data platform
Client
Cirro monitoring platform · Geotechnics
Year
2026
Role
Design and development

Putting every sensor on the same clock.

SmartSync, a reusable time-alignment engine for a commercial monitoring platform: one configurable grid, explicit gap rules and an honest label on every value.

Photo placeholder (P02): Screenshot: two sensor series in Cirro before and after SmartSync alignment.

Results

  • 3

    selection rules (nearest, linear, fill)

  • 5–15 min

    configurable grid intervals

  • SSE

    live job status streaming

Monitoring platforms combine sensors that report every minute, every fifteen minutes or whenever the modem wakes up. Comparing their timestamps directly produces differences, balances and alarms that are quietly wrong. I designed SmartSync so that alignment becomes one shared, configurable mechanism instead of a fix inside every calculation.

The problem

Different clocks, delays, lost samples, duplicates and out-of-order data meant that two series that looked aligned on a chart were not aligned in the numbers. Each new calculation solved it again, slightly differently.

What I built

  • A configurable time grid (5, 15 minutes and other intervals) with consistent anchors across series.
  • Selection rules per series: nearest neighbour, linear interpolation and forward-fill where the physics and the business rule allow it.
  • Temporal quality controls: maximum offset, time-to-live, age limits, duplicate removal and out-of-order handling.
  • Asynchronous jobs that can be exported and queried, with live status updates over Server-Sent Events.

The principle

Gaps are never filled without limit. Every output value states whether it is real, synchronised, interpolated or discarded, so anything downstream — differences, aggregates, balances, alarms and reports — can trust what it receives.

Gallery

  • Photo placeholder (P03): Diagram: time grid with nearest, linear and forward-fill rules and max-gap tolerance.
    One grid, three selection rules and an explicit maximum gap.
  • Photo placeholder (P04): Screenshot: SmartSync job settings (grid, tolerance, TTL, dedup) and live status.
    Job settings and live status, so long runs never block the user.

Services

  • Time-series data engineering
  • Platform & application software

Tools & tech

  • C#
  • .NET
  • TypeScript
  • React
  • SQL Server
  • Server-Sent Events

Got a similar challenge?Let’s talk.

Get in touch