Skip to content
Sector
Water & hydrogeology
Client
Mining client, Waikato · via Geotechnics
Year
2026
Role
Data transformation and reporting

Groundwater levels with the right reference.

Correct water levels from deep piezometers: reduced-level transforms, inclined-borehole geometry and two reporting resolutions from the same sensor.

Photo placeholder (P11): Field photo: piezometer borehole collar and sensor cable at the wellhead.

Results

  • 61

    vibrating-wire sensors summarised

  • ~20

    boreholes

  • 1 / 15 min

    control vs reporting resolution

A deep pumping well and a field of vibrating-wire piezometers fed both operational control and regulatory reporting. The numbers were only as good as the reference behind them: the collar level, the confirmed install depth and the difference between depth along an inclined hole and true vertical depth.

A level in the right frame

For one well, the instrument depth was confirmed at 162.03 m below ground, against a preliminary 161.3 m. I applied the reduced-level transform RL = collar RL − (install depth − h) from the confirmed date onwards, kept the earlier valid readings, and left the period without recoverable data as a declared gap instead of inventing values.

Two resolutions, two users

The pump operator needed one-minute data to control the pump; the reporting team needed fifteen-minute data that would not swamp their charts. Instead of choosing, I kept fine acquisition in the platform and delivered a fifteen-minute export over FTP.

Sixty-one sensors, one export

  • A temperature summary for 61 vibrating-wire sensors across about 20 boreholes: one row per device, including retired or damaged ones with their last month of data.
  • Full-history mean and standard deviation, the mean over each device’s own last month, and the vertical reference.
  • Vertical depth computed as collar RL minus sensor RL from the deviation survey — for one sensor about 185 m vertical against 198 m along the hole.

Gallery

  • Photo placeholder (P12): Sketch: inclined borehole, along-hole depth vs vertical depth, collar and sensor RL.
    Along-hole depth is not vertical depth: the sensor RL already carries the deviation.
  • Photo placeholder (P13): Chart: groundwater level in mRL, static vs pumping, 1-minute and 15-minute views.
    Static and pumping levels in mRL, at one-minute and fifteen-minute resolution.

Services

  • Scientific & engineering computation
  • Time-series data engineering
  • Regulatory & client data delivery

Tools & tech

  • Python
  • SQL
  • Cirro
  • FTP
  • Vibrating-wire piezometers

Got a similar challenge?Let’s talk.

Get in touch