- Sector
- Water & hydrogeology
- Client
- Mining client, Waikato · via Geotechnics
- Year
- 2026
- Role
- Data transformation and reporting
Groundwater levels with the right reference.
Correct water levels from deep piezometers: reduced-level transforms, inclined-borehole geometry and two reporting resolutions from the same sensor.

Results
61
vibrating-wire sensors summarised
~20
boreholes
1 / 15 min
control vs reporting resolution
A deep pumping well and a field of vibrating-wire piezometers fed both operational control and regulatory reporting. The numbers were only as good as the reference behind them: the collar level, the confirmed install depth and the difference between depth along an inclined hole and true vertical depth.
A level in the right frame
For one well, the instrument depth was confirmed at 162.03 m below ground, against a preliminary 161.3 m. I applied the reduced-level transform RL = collar RL − (install depth − h) from the confirmed date onwards, kept the earlier valid readings, and left the period without recoverable data as a declared gap instead of inventing values.
Two resolutions, two users
The pump operator needed one-minute data to control the pump; the reporting team needed fifteen-minute data that would not swamp their charts. Instead of choosing, I kept fine acquisition in the platform and delivered a fifteen-minute export over FTP.
Sixty-one sensors, one export
- A temperature summary for 61 vibrating-wire sensors across about 20 boreholes: one row per device, including retired or damaged ones with their last month of data.
- Full-history mean and standard deviation, the mean over each device’s own last month, and the vertical reference.
- Vertical depth computed as collar RL minus sensor RL from the deviation survey — for one sensor about 185 m vertical against 198 m along the hole.
Gallery

Along-hole depth is not vertical depth: the sensor RL already carries the deviation. 
Static and pumping levels in mRL, at one-minute and fifteen-minute resolution.
Services
- Scientific & engineering computation
- Time-series data engineering
- Regulatory & client data delivery
Tools & tech
- Python
- SQL
- Cirro
- FTP
- Vibrating-wire piezometers