Along-hole depth is not vertical depth
A sensor 198 m down an inclined borehole sits about 185 m below the collar. Small geometry, big consequences for every level you report.

Piezometers and other borehole sensors are installed at a depth measured along the hole. When the hole is inclined, that number is not the vertical distance to the sensor, and treating it as if it were shifts every derived water level.
Use the elevation, not the cable length
The reliable approach is to work in reduced levels. The deviation survey gives the elevation of each sensor tip, which already accounts for the inclination. Vertical depth is then simply the collar elevation minus the sensor elevation. The subtraction does no angular correction by itself; the survey already did.
A real example
- One vibrating-wire sensor: about 198 m along the hole, about 185 m vertically below the collar.
- A 13 m difference, far larger than the signals the client was trying to monitor.
- Keeping collar RL, sensor RL and their source in the device master made the correction traceable for all 61 sensors.
The same idea applies to every transform with a reference: datums, offsets, install depths. Store the reference next to the data, and the equation next to the reference.
Related articles
- Read moreData qualityPractice1 min read
Measured, interpolated, filled: label your data honestly
A chart line does not tell you which points a sensor actually recorded. Your data model should. Five labels that keep monitoring data trustworthy.
- Read morePracticeInstrumentation1 min read
One sensor, two products: ask what the data is for
The pump operator wanted one-minute data. The report needed fifteen-minute data. Both were right, and the answer was not a compromise.